One of the Best RAPS Inverters in the World! This is one amazing Inverter that really does have all the features & reliability you need. Be sure to read the Brochure & Manuals (PDFs below) to get all the details folks - no way it will all fit here! 24 Volt, 5000 Watt + 10KVA Generator output, 91%, Built-in Charger & More! OK here you have it - total remote dependance! You're drilling in the shed - the wife's doing the washing & the kettles on...then your son decides to arc up the welder - Zap! Not with the PS1. Quickly, quietly & effectively the PS1 detects the load, starts the generator & you don't even notice! This unit is a genuine No-Break unit - the power it delivers is constant & designed for the rugged & harsh climate & conditions of the Australian Outback. See Below for all specs - Very high power ratings for real household / farm / business use Rated at working temperatures not in non-existant lab conditions Built in High Amp Battery Charger Automated Data Logging & Programmable everything! Rated power is HUGE when used in connection with a generator (ie 5Kw Plus 10Kw = 15KW total!) Right Click & open this picture in a new window or save it to view properly!
4 line back lit LCD, much easier to read.
Completely new menu structure makes programming much faster.
Significantly improved electronics for greater reliability.
New ?State of Charge? reading replaces ?discharge Ah?, for simpler understanding
New aggressive software makes generator synchronising much faster and reliable.
Selectable Generator type or custom settings improves generator stability
Auto control of generator further enhanced with ?time of day? control.
Auto control of generator will provide emergency power if inverter is out of service
No power disturbances during starting and stopping of generator
View up to 32 daily events directly on the LCD without modem or PC.
Enhanced user adjustability
Individual display of internal and external shunt current & display of Nett battery current
Sums generator and inverter outputs together if required for peak load.
Vastly improved LED layout allows quick glance status check
Programmable Load Search & reduced low load losses.
Greatly improved documentation
Much simpler installation and easier field PCB replacement
Physically smaller than previous RAPS unit.
? Science & education projects
CAN BE USED ON IT'S OWN OR IN COMBINATION WITH GRID / GENERATOR POWER!!
Manual | Technical | Brochure |
Specifications: | PS1 RAPS 5/24 | PS1 RAPS 6/48 | PS1 RAPS 10/48 | PS1 RAPS 11/108 | PS1 RAPS 12/120 |
Inverter Mode | |||||
Battery Voltage, Nominal | 24V DC | 48V DC | 48V DC | 108V DC | 120V DC |
Battery Voltage, default range | 22 - 34 V | 44 - 68 V | 44 - 68V | 88 - 150V | 98 - 170V |
Cont. output power @ 25?C | 5kW | 6kW | 10kW | 11kW | 12kW |
Cont. output power @ 30?C | 4.5kW | 5.5kW | 9kW | 10kW | 11kW |
Cont. output power @ 40?C | 4kW | 5kW | 8kW | 9kW | 10kW |
Cont. output power @ 50?C | 3.2kW | 4kW | 6.4kW | 7.2kW | 8kW |
Cont. output power @ 60?C | 2kW | 2.5kW | 4kW | 5kW | 5.5kW |
Max output power, 5 mins (initial power <1kW) | 6.5kW | 8kW | 13kW | 13kW | 16kW |
Max overload 0-5 seconds | 8kW | 10kW | 16kW | 20kW | 22kW |
Max continuous output-interactive mode | 5kW + gen output | 6kW + gen output | 10kW + gen output | 11kW + gen output | 12kW + gen output |
Max continuous AC output current | 21A + gen output | 25A + gen output | 42A + gen output | 46A + gen output | 50A + gen output |
Max continuous DC input/output current | 250A DC | 150A DC | 250A DC | 120A DC | 120A DC |
DC input, load search, no AC load | 0.6A/15W | 0.3A/15W | 0.3A/15W | 0.12A/15W | 0.12A/15W |
Load search sensitivity range | 5-40W | ||||
Output voltage/frequency- invert mode, zero to max load, max or cont | 240V AC +1%/-4%, 50Hz +/-.01% @ <4% THD | ||||
Interactive Mode | |||||
Changeover time, invert to generator | Zero | ||||
Maximum supported generator capacity | 10kVA | 15kVA | 20kVA | 30KVA | 30kVA |
Load auto switched to generator in fault mode | Yes | ||||
Max adjustable charge rate | 0-200A | 0-120A | 0-200A | 0-100A | 0-100A |
No of charge stages | 4 stages, plus equalise and recovery | ||||
Charger type | Unity PF: 4 state constant I, constant V with current & power limit | ||||
Charger settings | Adjustable to suit all battery types, default: sealed | ||||
Generator Start Parameters | |||||
4 x time of day, 3 x state of charge | |||||
2 x adjustable power limits, 4 x back up times | |||||
Battery voltage, inverter shutdown | |||||
Inverter temperature | |||||
Generator start method | 2 or 3 wire, pulsed or run signal (adj.) | ||||
General | |||||
Unit weight/packed weight | 72kg/78kg | 73kg/80kg | 87kg/94kg | 93kg/100kg | 93kg/100kg |
Dimensions | 585mm High x 400mm Wide (430mm incl. mounting flanges) x 420mm Deep | ||||
Communications serial interface | RS232 @ 2400bps | ||||
Memory retention of settings and logged data | Permanent via on board battery backed RAM & EEPROM | ||||
No. of Shunts | 1 x 100A internal, 1 x optional external shunt | ||||
Circuit breaker for generator input | 63A | 63A | 125A | 125A | 125A |
Circuit breaker for AC output | 63A | 63A | 125A | 125A | 125A |
Circuit breaker for DC battery input, | 250A* | 125A | 250A | 125A | 125A |
Standards | C tick, AS3100 | ||||
Efficiency: Peak | 91% | 93% | 96% | 96% | 96% |
@ 10% & 30% nominal load | 87% - 91% | 85% - 93% | 91% - 96% | 90% - 95% | 90% - 95% |
@ 50% & 100% nominal load | 91% - 90% | 93% - 92% | 96% - 93% | 96% - 94% | 96% - 94.5% |
Safety isolation | AC output to chassis & battery 5kV, battery to chassis 1kV | ||||
Power factor charging | Unity | ||||
Power factor inverting | 0-1 | ||||
Enclosure rating | IP40 | ||||
Cooling method | 2 x thermostatically controlled fans | ||||
Protection | Circuit breakers on all external power connections, plus electronic trip of DC breaker* & reverse battery on all units except PS1 RAPS 5/24 | ||||
On board log | Records over 200 events, alarms and data which can be accessed remotely via serial port/modem. Up to 32 current day events on LCD | ||||
Four line alphanumeric backlit LCD displays: | Configuration parameters, Batt Volts, Nett Batt Amps, AC Load kW, Gen kW/Volts/Freq, Avg daily kWh, Shunt 1&2 Amps, Event log, Charge Amps, State of Charge | ||||
Warranty | 1 year, or 2 years when installed by a Selectronic accredited install |